Lens Selection Guide
5,000
3,000
2,000
1,000
500
300
200
100
50
4 5 10 20 30 50 100 200 300 500
Note: All values are approximate values. It is recommended that the camera distance
be adjusted by sliding the camera forward or backward in actual operation.
Camera distance A (mm)
Field of view L (mm)
Optical Graph
t: Extension Tube thickness
Lens model: F150-________
L75
L50
L25
L16
L12
L8
Field of view
L (mm)
Extension Tube
Lens
Camera
Camera distance
A
(mm)
Unit: mm
30 dia.
Total length
1" -32UN
-2A
Max.
outer
dia.
F150-L8
29 dia. x 34.5 L*
8.0 mm
F1.3
F150-L12
30 dia. x 34.5 L*
12.5 mm
F1.4
F150-L16
30 dia. x 24.5 L*
16.0 mm
F1.4
F150-L25
30 dia. x 24.5 L*
25.0 mm
F1.4
F150-L50
32 dia. x 37 L*
50.0 mm
F1.8
F150-L75
32 dia. x 42.5 L*
75.0 mm
F2.7
Model
Dimensions
Focal length
Brightness
CCTV Lens
First: Start by defining the field of view requirements for each camera. Refer to the diagram at bottom left. The
field of view is considered to be the area or areas requiring inspection. This does not necessarily include the
entire part or object in the field of view.
Second: Determine the camera distance, measured from the object surface to the camera. Refer to the lens setting illustration for
additional information about setting distance. This distance can impose limitations on the field of view and lens choice.
To get the greatest flexibility in lens selection, keep the camera setting distance as flexible as possible.
Third: Using the field of view and camera setting distance requirements, use the optical graph axis marked "Field of view L (mm)"
to find the matching field of view size. Use the optical graph axis marked "Camera distance A (mm)" to find the approximate
camera setting distance. Follow the values across the chart until they cross. Refer to the lens part reference on the right at
the end of the graph line to find the correct lens size. (If a "t" value other than 0 is indicated, corresponding lens extension
tubes will need to be added in between the camera and lens in order to properly focus the image. The "t" value indicates the
thickness of the extension tubes required.)
Note: Extension tube length should not exceed 10% of the focal length of the lens. When looking at other manufacturers
lenses not referenced by Omron, please use a 1/3-inch CCD size as a selection value reference.
Fourth: If an appropriate lens cannot be found to satisfy your application, please consult your Omron vision representative for
additional assistance in lens selection options.
* Lens diameter does not include lens ring lock screw height.
Note: Omron reserves the right to change lens suppliers and specifications without notification. Please verify all lenses with sales personnel.